home *** CD-ROM | disk | FTP | other *** search
/ Cream of the Crop 11 / Cream of the Crop 11-1.iso / lan / 3c589x.zip / 3C589X.EXE / DIAG / TROUBLE.TXT < prev   
Text File  |  1995-08-25  |  2KB  |  43 lines

  1. Troubleshooting
  2.  
  3. If the EtherLink III LAN PC Card diagnostic tests fail, 
  4. the PC Card may not be defective.
  5.  
  6. Check the following:
  7.  
  8. 1. Make sure that the  PC Card is operating in a computer 
  9.    containing the PC Card standard Type II or Type III slots.
  10.  
  11. 2. Make sure that the PC Card is completely seated in its 
  12.    slot. Review the installation instructions in the 
  13.    EtherLink III LAN PC Card user guide.
  14.  
  15. 3. Make sure that your computer is running DOS 3.1 or 
  16.    higher and that no device drivers or memory managers are 
  17.    loaded.
  18.  
  19. 4. Inspect all cables and connections.
  20.  
  21. 5. If you are running the Echo Exchange test, make sure 
  22.    that the EtherLink III LAN PC Card is securely connected 
  23.    to a properly cabled network and an echo server is set up 
  24.    on the network.
  25.  
  26. 6. If you are configuring the I/O base address or interrupt 
  27.    request level make sure that the settings you select for 
  28.    these parameters do not conflict with any other peripheral 
  29.    or software program installed in the computer. If your 
  30.    computer has Card Services, these parameters are set 
  31.    automatically, and you cannot change them.
  32.  
  33. 7. The computer in which the EtherLink III LAN PC Card 
  34.    is installed may be defective.  Install the PC Card in a 
  35.    known functioning computer and run the tests again.
  36.  
  37. 8. Replace the failed EtherLink III LAN PC Card with a 
  38.    known working PC Card, with the same configuration. If 
  39.    the second PC Card fails, something is probably wrong 
  40.    with the test environment, not with the PC Card.